Specs page 3 of 3
User supplied power supply requirements are
linear- or switched-mode low voltage supplies such as a standard car-battery charger (with large electrolytic capacitor connected, see our documentation for safety and construction details). Any 24V-80V, 12-28Amp DC-current supply is acceptable but, in general, highest feed-rates and max. torque are depending on power supply capabilities.
We supply Professional Power Consoles
for operating 4-axes simultaneously of the 3-phase 415VAC/230VAC 50-60Hz grid with additional functions.
Additional functions are:
- Vacuum on/off by RF 433Mhz remote control
- Machine on/off by RF 433Mhz remote control
- Both on/off functions have a manual override switch and can be switched on/off by a remote computer via an Optically Isolated Host I/O interface
- Clearly visible, 360° around controller console, High Intensity status LEDs
Electrical
- Controller Supply Voltage 415+230+Ground [50/60Hz] V(AC)
- To be fused with external fuses of 3x32 Amp
- Max. Power Load 6.8 kW
- Console power cable of 6 meters with wander plugs included
- Pre-wired pump is available for use as BLOWER or as VACUUM pump
Operating Conditions
- Temperature 18 – 35 ˚C
- Relative Humidity 30-90 %
- Noise 42 dB(A) ****
**** without pump; with included silencer and depending on physical mounting/location of vacuum pump ~ 72dB(A)